Digitus CAT 7A S/FTP installation cable, 100 m, simplex, Dca-s1a d1 a1

SKU
DK-1743-A-VH-1
Login for pricing
In stock
CAT 7A S-FTP installation cable, 1500 MHz Dca, AWG 22/1, 100 m ring, Sx, yellow
  • Physical properties:
  • Conductor: Bare copper wire, AWG 22/1
  • System(s) of assessment and verification of constancy of performance: System 3
  • Insulation: SFS-PE (foamed polyethylene jacket)
  • Total number of insulated conductors: 8, twisted into 4 pairs
  • Color code: blue-white, orange-white, green-white, brown-white
  • Shielding of the individual pairs: Aluminum-laminated polyester film, covers 100%
  • Overall shielding: tinned copper braiding
  • Outer sheath: Dca-s1a d1 a1acc. to EN 50575; LSZH
  • Outer sheath thickness (nominal): 0.60 mm (Dca); 0.60 mm (Cca)
  • Outer sheath color: Yellow (RAL 1028)
  • Mechanical properties:
  • Strain relief: 150N max.
  • Dynamic bending radius: 8x AD mm min.
  • Static bending radius: 4x AD mm min.
  • Transport and storage temperature range: -20 °C to +60 °C
  • Operating temperature range: -20 °C to +60 °C
  • Installation temperature range: 0 to +50C
  • Outer diameter (nominal): 7.8 mm (Dca); 7.8 mm (Cca)
  • Weight (kg/km): 65 kg (Dca); 65 kg (Cca)
  • Electrical properties:
  • Impedance: 100±5 Ohm @ 1-1000 MHz
  • Capacitance: 40 pF/m nominal @ 1 KHz
  • Capacitance unbalance (pair-earth): 1.6 pF/m max. @ 1 KHz
  • Insulation resistance: 5 GOhm x km min.
  • Loop resistance: 147 Ohm/Km max. (2% max. unbalanced resistance)
  • Operating voltage: 72 VDC max.
  • Coupling attenuation: CA-Type 1b
  • Phase delay: 450 nS/100 m max.
  • Time delay: 10 nS/100 m max.
  • Separation class: "d" according to EN 50174-2
  • NVP: 79%
  • Flame spread: EN 60332-1-2 (LSOH-PVC)
  • Halogen-free, corrosiveness: EN 60754-1/2 (LSOH)
  • Smoke density: EN 61034-2
More Information
Cable length 100 m
Connector 2 No
Connector 1 No
Cable shielding S/FTP (S-STP)
SKU DK-1743-A-VH-1
EAN 4016032462828
Manufacturer Digitus
Availability N
Future-oriented standards and high-end quality for your network.

- 10 GBit Ethernet
- 1500 MHz transmission frequency
- Permanent link certified
- PoE Power over Ethernet support
- BauPVO category Dca-s1a d1 a1

The Digitus Cat 7 installation cable is designed for use in the structured data center and the building cabling according to ISO/IEC 11801, DIN EN 50288-4-1, DIN EN 50173, IEC 61156-7, EN 50288-9-1. The cable is perfectly suitable for the transmission of both analog and digital data and also supports POE and POE+. The shielding structure is composed of single shielded pairs with a tinned copper braid, which ensures excellent shielding and electrical values.
Features
Product colourYellow
Country of originChina
Conductor materialCopper
Frequency1500 MHz
AWG wire size22/1
Cable standardCat7a
Cable shieldingS/FTP (S-STP)
Connector 1No
Connector 2No
Data transfer rate10000 Mbit/s
Jacket materialLow smoke zero halogen (LSZH)
Conductor typeSolid
Cable length100 m
Power over Ethernet (PoE)Yes
Connector 2 genderNo
Connector 1 genderNo
CertificationCPR class Dca
Harmonized System (HS) code84733080
Operational conditions
Storage temperature (T-T)-20 - 75 °C
Operating temperature (T-T)-20 - 60 °C
Sustainability
Doesn't containHalogen
Certificates
CertificationCPR class Dca
Packaging content
Quantity per pack1 pc(s)
Packaging data
Package volume12544 cm³
Package width280 mm
Package depth280 mm
Package weight5.68 kg
Quantity per pack1 pc(s)
Technical details
Product colourYellow
Cable standardCat7a
Cable shieldingS/FTP (S-STP)
Connector 1No
Connector 2No
Data transfer rate10000 Mbit/s
Jacket materialLow smoke zero halogen (LSZH)
Conductor typeSolid
Cable length100 m
Country of originChina
Doesn't containHalogen
Logistics data
Master (outer) case gross weight5.68 kg
Master (outer) case volume12544 cm³
Master (outer) case width280 mm
Master (outer) case length280 mm
Master (outer) case height160 mm
Harmonized System (HS) code84733080
UK Trade Tariff code85444920

You may also be interested in

Compare Products
Product Digitus CAT 7A S/FTP installation cable, 100 m, simplex, Dca-s1a d1 a1
Bestseller
Digitus CAT 7A S/FTP installation cabl... Login for pricing
connektgear 305m Solid CAT5e UTP Network Cable Drum - 24AWG - Grey connektgear 305m Solid CAT5e UTP Netwo... Login for pricing
APC Dry contact, Management Options, Dry Contact I/O Accessory, additional dry contact input and relay outputs
Hot Product
APC Dry contact, Management Options, D... Login for pricing
StarTech.com Bulk Cat 5e Ethernet Cable - 1000 ft. (304,8m) - Solid - CMR-Rated - Blue - TAA Compliant StarTech.com Bulk Cat 5e Ethernet Cabl... Login for pricing
LogiLink CPV0018 networking cable Beige 305 m Cat5e LogiLink CPV0018 networking cable Beig... Login for pricing
StarTech.com Bulk Cat 5e Ethernet Cable - 1000 ft. (304,8m) - Solid - CMR-Rated - Gray - TAA Compliant StarTech.com Bulk Cat 5e Ethernet Cabl... Login for pricing
SKU
DK-1743-A-VH-1
28-0305SG
AP9810
WIRC5ECMR
CPV0018
WIRC5ECMRGRY
Manufacturer
Digitus
connektgear
APC
StarTech.com
LogiLink
StarTech.com
Connector 2
N
N
N/A
N
N
N
Connector 1
N
N
N/A
N
N
N
Cable shielding
S/FTP (S-STP)
U/UTP (UTP)
N/A
U/UTP (UTP)
N/A
U/UTP (UTP)
Cable standard
Cat7a
Cat5e
N/A
Cat5e
Cat5e
Cat5e
Cable length
15m and more
15m and more
0m to 1m
15m and more
15m and more
15m and more