Broadcom MegaRAID 9670W-16i RAID controller PCI Express x8 4.0 6 Gbit/s

SKU
05-50123-00
Login for pricing
In stock
PCI Express 4.0 x8, 6Gb/s, 3 x SAS SFF-8654 x8, RAID 0/1/5/6/10/50/60
The MegaRAID 9600 series is the third generation of Tri-Mode x8 and x16 NVMe/SAS/SATA adapters. Designed to deliver the best possible performance for NVMe SSD-based storage systems, the 9600 family delivers 2x the bandwidth, over 4x the IOPs, 25x reduction in write latency and 60x increase in performance during rebuilds over the previous generation.

The MegaRAID 9670-24i adapter, based on the SAS4124 RAID-on-Chip (RoC), integrates a 2x72-bit high-speed DDR memory interface delivering faster speeds at 3,200 MT/s and more than 4x increase in RAID5 Random Write IOPs over previous generation adapters. Gain the most flexibility out of your storage controller by direct connecting up to 24 Gen 4.0 NVMe, 24G SAS or SATA devices.
SKU 05-50123-00
EAN 0830343007783
Specification
Ports & interfaces
Supported storage drive interfacesSAS, Serial ATA
Internal SAS ports3
Host interfacePCI Express x8
PCI Express slots version4.0
Performance
RAID levels0, 1, 5, 6, 10, 50, 60
SSD supportYes
S.M.A.R.T. supportYes
Number of devices supported240
Mean time between failures (MTBF)3000000 h
Form factorMD2
Data transfer rate6 Gbit/s
Channels quantity24 channels
CertificationAustralia/New Zealand RCM (AS/NZS CISPR 32; CISPR 32:2015, Class A; AS/NZS CISPR 32:2015, Class A), Canada EMC (ICES-003:2016 Issue 6: 2016, Class A; CAN/CSA CISPR 22-10; CISPR 22:2008), Europe (CE) (EN 55024, EN 55032, EN 55035; EN 55032:2015 +AC:2016, Class A; EN 55024:2010 +A1:2015; EN 55035:2017 +A11:2020), Korea (KN32/KN35), Taiwan BSMI (CNS 13438; CNS15663), USA/Canada Safety (UL Listed) (UL 62368-1, Second Edition; CAN/CSA C22.2 No. 62368-1-14), USA/Canada (FCC) (47 CFR FCC Part 15, Subpart B, Class A; ANSI C63.4:2014; CISPR 32:2008) CB (IEC 62368-1:2014 (Second edition); EN 62368-1:2014+A11: 2017), Japan (V-3/2015.04, Class A; V-4/2012.04; VCCI-CISPR 32:2016; CISPR 32:2015), Morocco (CMIM) (EN 55024, EN 55032, EN 55035; EN 55032:2015 +AC:2016, Class A; EN 55024:2010 +A1:2015; EN 55035:2017 +A11:2020)
Data transmission
Data transfer rate6 Gbit/s
Technical details
RAID levels0, 1, 5, 6, 10, 50, 60
SSD supportYes
S.M.A.R.T. supportYes
Number of devices supported240
Form factorMD2
Channels quantity24 channels
Compliance certificatesRoHS, WEEE
Design
Form factorMD2
Endurance
Mean time between failures (MTBF)3000000 h
Power
Power consumption (typical)24 W
Certificates
CertificationAustralia/New Zealand RCM (AS/NZS CISPR 32; CISPR 32:2015, Class A; AS/NZS CISPR 32:2015, Class A), Canada EMC (ICES-003:2016 Issue 6: 2016, Class A; CAN/CSA CISPR 22-10; CISPR 22:2008), Europe (CE) (EN 55024, EN 55032, EN 55035; EN 55032:2015 +AC:2016, Class A; EN 55024:2010 +A1:2015; EN 55035:2017 +A11:2020), Korea (KN32/KN35), Taiwan BSMI (CNS 13438; CNS15663), USA/Canada Safety (UL Listed) (UL 62368-1, Second Edition; CAN/CSA C22.2 No. 62368-1-14), USA/Canada (FCC) (47 CFR FCC Part 15, Subpart B, Class A; ANSI C63.4:2014; CISPR 32:2008) CB (IEC 62368-1:2014 (Second edition); EN 62368-1:2014+A11: 2017), Japan (V-3/2015.04, Class A; V-4/2012.04; VCCI-CISPR 32:2016; CISPR 32:2015), Morocco (CMIM) (EN 55024, EN 55032, EN 55035; EN 55032:2015 +AC:2016, Class A; EN 55024:2010 +A1:2015; EN 55035:2017 +A11:2020)
System requirements
Server operating systems supportedSUSE Linux Enterprise Server
Windows operating systems supportedYes
Linux operating systems supportedYes
Other operating systems supportedVMware vSphere ESXi
Operational conditions
Operating temperature (T-T)0 - 55 °C
Operating relative humidity (H-H)5 - 90%
Weight & dimensions
Width155.6 mm
Depth111.1 mm
Other features
Other operating systems supportedVMware vSphere ESXi
Manufacturer Broadcom
In Stock Y