ATEN 20A/16A 30-Outlet 3-Phase Metered eco PDU

SKU
PG95230G-AT
Login for pricing
In stock
20A/16A 30-Outlet 3-Phase Metered eco PDU
When maintaining operating uptime in a data center or server room, sustainable energy efficiency can make all the difference. The implementation of effective power management often involves improvements at both the hardware and software level. As the trend for 3-phase power grows due to its efficiency to generate, transfer, and distribute electricity, ATEN is introducing its latest PG series of PDUs, available in IEC socket configuration, that are designed with 0U rack housing to accommodate the increasing demand for power to high-density IT equipment in server rooms and data centers. Each PG95230 PDU, utilizing an ARM-Cortex A8 processor, is equipped with 30 port outlets capable of running at higher voltages, powers up all connected equipment in less than 10 seconds once plugged in, and delivers the most accurate kWh energy usage data (+/-1%) for better power consumption habits, baselines, and initiative tracking. With energy saving in mind, the PG95230 is purposed to enable lower energy consumption for best practice in a network infrastructure, while promoting up to 70.65 kg (131.4 kw equivalent of power consumption) of reduced CO2 emission, reduced electricity expenses, and lower carbon taxes to pay each year.

Secure Locking Enhancement
The outlets can be protected with a secure lock to prevent power cords from becoming unplugged due to vibration or human errors.

Real-time Alerts via LCD Display
The illuminated LCD display can display warnings to alert users of unusual power states.

Hot-Swappable Function
The LCD console panel is hot-swappable and can be removed, replaced, or repaired without powering down a mission-critical connected load.

Dual LAN Ports for Scalable Network Setup
The PG95230 is equipped with dual LAN ports (e.g. Internet and Intranet) supporting up to 1G Ethernet connection, and can be cascaded to connect up to 64 PDUs, saving expense on installing extra network switches to incorporate network connections while sparing more rack space to accommodate more IT equipment in an expandable network.

Environment Sensors
The Sensor port enables RJ-45 connectivity to connect or daisy-chain up to 8 environment sensors for monitoring and management of temperature, humidity, airflow, differential air pressure, and leaks, featuring alerts for potential threats.

Flexible On-Site Network Operation
For quick operation, connecting a serial device to the PDU with its COM port provides another means to undertake communication via CLI commands. In addition, the same port is also functional as a PON port, available for Ethernet connection to a KN series KVM over IP Switch to centralize power management of up to 16 daisy-chained PDUs.

Networkable via WiFi
The PG95230 can be networked via connection to a USB WiFi dongle to perform DCIM, firmware upgrade, log export, quick configuration, and more.

Adjustable Power Cord for Flexible In-Rack Installation
The PG95230 comes with an adjustable power cord built in to the unit capable of 90-degree rotation to allow flexible in-rack installation, resulting in better cable organization.

DCIM Monitoring
Integrated with ATEN’s eco DC – a PC- and web-based tool for optimized Data Center Infrastructure Management (DCIM) – power distribution, energy, and environmental data from PDUs and connected devices can be monitored via a friendly web GUI for smart power management.

Colored Panel for Smarter Power Monitoring
The PG series PDUs feature a LCD console panel in default red and can be re-colored with options of yellow, purple, blue, and green through optional purchase of colored stickers. These color codes make it easier to differentiate between power feed settings and also speed up troubleshooting in case of unexpected failures.

Applications
The PG series 3-Phase PDUs are perfectly suited to server rack installation requiring energy-efficient power distribution to high-density IT equipment in a server room or data center.
SKU PG95230G-AT
Specification
Design
TypeThree-phase
PDU typesMetered
DisplayLCD
Product colourBlack
Rack capacity0U
Ports & interfaces
USB ports quantity1
AC outlets quantity30 AC outlet(s)
AC outlet typesC13 coupler, C19 coupler
Power plugIEC309
Ethernet LAN (RJ-45) ports4
Features
Cable length3 m
Daisy chainYes
Security algorithmsTLS
Reset buttonYes
Management features
Supported network protocolsIPv6, SMS
Management protocolsTCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, ARP, NTP, DNS, Auto Sense, Ping, SNMP V1&V2&V3, Telnet, Modbus
MonitoringCurrent, Humidity, Power, Temperature, Voltage
Ergonomics
Cable length3 m
DisplayLCD
Power
Nominal input voltage400 V
Nominal output voltage230 V
Maximum current16 A
Load capacity11084 VA
AC input frequency50 - 60 Hz
Number of phases3
Circuit breakerNo
Weight & dimensions
Weight7.34 kg
Width56 mm
Depth1790 mm
Height68 mm
Package width229 mm
Package depth1945 mm
Package height179 mm
Package volume79853.5074 cm³
Package weight9.72 kg
Packaging data
Package width229 mm
Package depth1945 mm
Package height179 mm
Package volume79853.5074 cm³
Package weight9.72 kg
Packaging content
ManualYes
Rack mount kitYes
Operational conditions
Operating temperature (T-T)0 - 60 °C
Storage temperature (T-T)-20 - 60 °C
Storage relative humidity (H-H)0 - 80%
Operating relative humidity (H-H)0 - 80%
Technical details
Sustainability complianceYes
Compliance certificatesCE
Security
Security algorithmsTLS
Logistics data
Master (outer) case width229 mm
Master (outer) case length1945 mm
Master (outer) case height179 mm
Master (outer) case gross weight10.1 kg
Master (outer) case volume79853.5074 cm³
Master (outer) case net weight7.5 kg